Kostech
Kostech
Mira Road, Thane, Maharashtra
GST No. 27BNZPS5350L1ZY
TrustSEAL Verified
Call 0804898557882% Response Rate
SEND EMAIL

Oxygen Analyzer

Leading Manufacturer of oxygen analyzers from Thane.

Oxygen Analyzers

Oxygen Analyzers
  • Oxygen Analyzers
  • Oxygen Analyzers
  • Oxygen Analyzers
  • Oxygen Analyzers
Get Best Quote
Approx. Price: Rs 25,000 / PieceGet Latest Price

Product Details:

Minimum Order Quantity1 Piece
Model Name/NumberUltrasonic Oxygen Analyzer, Concentration, Flow Rate, Pressure for Oxygen Concentrator I Oxygen Conc
BrandKostech
Usage/ApplicationCheck Oxygen Purity,Check Oxygen Concentration,Check Oxygen Flow Rate ,Check Oxygen Pressure
Product TypeOxygen Analyzer
Power SupplyChargeable Battery
Automation GradeSemi-Automatic

Ultrasonic Oxygen Analyzer Product Introduction: ?RP-01 ultrasonic oxygen analyzer is a measuring instrument. It has been developed for use with PSA oxygen concentrators to measure oxygen concentration, flow rate and outlet pressure. ?The RP-01 does not need to be recalibrated. ?The oxygen concentration measurement is based on the different sound propagation times in oxygen and nitrogen. For the flow measurement, different sound propagation times in the flow direction and against the flow direction are evaluated. ?The pressure measurement is carried out by means of a pressure measuring cell. Notes: ?The service life of RP-01 is more than 5 years. ?The product detects the gas output from the concentrator only. ?You must remove the humidifier bottle prior to connecting the analyzer to the oxygen concentrator. ?The RP-01 features a built-in rechargeable battery. ?The RP-01 and all accessories that comes into contact with oxygen should be kept free of oil and grease. ?Do not smoke or expose to fire during use. ?When not in use, keep in a cool dry place. Do not leave in locations exposed to excessive heat, such as car. ?If the device has been stored at temperatures below 5°C, the device must be adjust to the room temperature, otherwise malfunctions may occur. Only measure at room temperature. ?Use a damp cloth to clean the surface with a small amount of alcohol. Do not spray with alcohol in case it enters the pipeline. Do not immerse in water. ?RP-01 should only be used by trained technicians. It is not intended for use by patients, nor to continuously monitor oxygen therapy delivery to patients. Please note that oxygen concentrators require routine preventative maintenance and repair.
Request
Callback


Additional Information:

  • Packaging Details: Standard
Yes! I am interested
X

Explore More Products

View All Products




Reach Us
Chandra Prakash (Marketing Manager)
Kostech
G-101, Navjivan Sheetal Ashish Bldg., Sheetal Nagar, Mira Road (East), Thane
Thane - 401107, Maharashtra, India
Get Directions


Call Us


Send E-mail